Symptom
You select Send in Barcode Simulator PowerTool, but nothing appears in the receiving app. Or the value appears, but the app doesn’t treat it as a scan.
Applies to
Any receiving app on the same Windows computer.
Cause
- The receiving app isn’t open, or its window title doesn’t contain the Target Window Keyword.
- The receiving window wasn’t ready when the keystrokes were sent.
- The receiving app needs the keystrokes spaced out, or expects a different prefix or suffix.
Resolution
- Make sure the receiving app is open on the same computer.
- In Barcode Simulator PowerTool, select Settings and check that Target Window Keyword is a word in the receiving window’s title.
- Increase Send Delay (ms), then select Save and send again.
- If the value appears but isn’t read as a scan, compare Send Prefix / Suffix against what the receiving app expects.
- If it still isn’t read as a scan, set Typing Delay per key (ms) to 10–30, then select Save and send again.
How to confirm it worked
Send a barcode again. The receiving window comes to the front and handles the value as a scan.
Still need help?
Ask other Business Central users in the Insight Works community, or send the details to the support team. Include the steps you took and any error message you saw.