Symptom

You select Send in Barcode Simulator PowerTool, but nothing appears in the receiving app. Or the value appears, but the app doesn’t treat it as a scan.

Applies to

Any receiving app on the same Windows computer.

Cause

  • The receiving app isn’t open, or its window title doesn’t contain the Target Window Keyword.
  • The receiving window wasn’t ready when the keystrokes were sent.
  • The receiving app needs the keystrokes spaced out, or expects a different prefix or suffix.

Resolution

  1. Make sure the receiving app is open on the same computer.
  2. In Barcode Simulator PowerTool, select Settings and check that Target Window Keyword is a word in the receiving window’s title.
  3. Increase Send Delay (ms), then select Save and send again.
  4. If the value appears but isn’t read as a scan, compare Send Prefix / Suffix against what the receiving app expects.
  5. If it still isn’t read as a scan, set Typing Delay per key (ms) to 10–30, then select Save and send again.

How to confirm it worked

Send a barcode again. The receiving window comes to the front and handles the value as a scan.