## Symptom

You select **Send** in Barcode Simulator PowerTool, but nothing appears in the receiving app. Or the value appears, but the app doesn’t treat it as a scan.

## Applies to

Any receiving app on the same Windows computer.

## Cause

- The receiving app isn’t open, or its window title doesn’t contain the **Target Window Keyword**.
- The receiving window wasn’t ready when the keystrokes were sent.
- The receiving app needs the keystrokes spaced out, or expects a different prefix or suffix.

## Resolution

1. Make sure the receiving app is open on the same computer.
2. In Barcode Simulator PowerTool, select **Settings** and check that **Target Window Keyword** is a word in the receiving window’s title.
3. Increase **Send Delay (ms)**, then select **Save** and send again.
4. If the value appears but isn’t read as a scan, compare **Send Prefix / Suffix** against what the receiving app expects.
5. If it still isn’t read as a scan, set **Typing Delay per key (ms)** to 10–30, then select **Save** and send again.

## How to confirm it worked

Send a barcode again. The receiving window comes to the front and handles the value as a scan.