# Configure Device Columns and Personalize Profiles in Warehouse Insight

The following helps you to set column visibility, column order, and column width in Warehouse Insight. You can set columns for one user and device, or set default columns for all users and devices.

## Understand column configurations

### Global configurations

Business Central stores the global configurations. These configurations set the default column layout for Warehouse Insight applications. All users and devices can use these defaults.

To view or change a global configuration in Business Central for a specific Warehouse Insight Application, go to _Warehouse Insight Applications_ / Select Application Code / Ribbon / **Columns**.

To view all Warehouse Insight Application Columns, search for _Warehouse Insight Device Columns_ in Business Central.

When adding new column records, always use the existing Table Nos. found in the _Warehouse Insight Device Columns_.

If desired, you can use alternative tables, but those require filter formulas. Please reach out to support if you require assistance using alternative tables and writing configuration formulas.

You can also use **Transfer Profile** on a Warehouse Insight device to replace the corresponding global configurations. A change to a global configuration does not automatically replace an existing user/device profile.

### User/device profiles

A user/device profile applies to one user on one device. It controls the columns the user sees, their order, and their widths. The profile does not automatically apply to another user or device.

If a user/device profile has column settings, Warehouse Insight uses those settings instead of the global configurations. Use **Clear Profile** to return to the global configurations.

## Open the profile actions

On the Warehouse Insight device, follow this menu path:

**Main Menu** / **Menu** / **Configure** / **Enter Password** / **Data**

The default password is 1234. Your organization can use a different password.

### Transfer Profile

Use **Transfer Profile** to copy the column settings from the current user/device profile to Business Central. This action replaces the corresponding global configurations. Other users can use the new defaults after they use **Clear Profile**.

### Clear Profile

Use **Clear Profile** to remove column settings for all users on the device. Warehouse Insight then uses the global configurations that are stored in Business Central. This action does not change or delete the global configurations.

## Set standard columns for users and devices

1. Select one user and one device to maintain the standard column layouts (use this user/device combination as the master profile).
2. Open an application on the master device (e.g., Receiving).
3. Set the column visibility, order, and widths.
4. Navigate to **Main Menu** / **Menu** / **Configure** / **Enter Password** / **Data** / **Transfer Profile** and enter the configuration password (1234 by default).
5. Repeat steps 2 to 4 for other applications that need standard column layouts (e.g., Item Inquiry).
6. Optional: Review the settings (in Business Central) in _Warehouse Insight Applications_ / _Columns_ FactBox / **Menus** / **Configure** (if the interface shows a bold “Columns” label, select it to open the menu).
7. Navigate to **Main Menu** / **Menu** / **Configure** / **Enter Password** (1234 by default) / **Data** / **Clear Profile** for each other user/device combination that must use the new defaults.

## Important information

- **Transfer Profile:** This action replaces the corresponding global configurations. Restrict this action to the selected master user/device combination when possible.
- **Clear Profile:** This action removes the column settings for the current user/device combination. You cannot use it to restore those local settings.
- **Synchronization:** Changes to the global configurations do not automatically replace existing user/device profiles. Use **Clear Profile** on each applicable user/device combination.
- **Column widths:** Set the total width of visible columns to fit the available screen width in pixels. If the columns are too wide, Warehouse Insight can resize them automatically, or the user must scroll horizontally to see all columns.